search

Press ENTER to search or ESC to close

OXITEST Oxidation Stability Reactor

Innovative accelerated oxidation test for the determination of the oxidation stability of fats on the whole sample according to AOCS Cd-12c-16.
Contact a specialist Find a dealer
Add to favorites
OXITESTF30900248
OXITESTF30910248
Close

Fats and oils oxidation stability tests for R&D and QC Labs

Fats and oils oxidation stability tests for R&D and QC Labs


The oxidation stability tests performed with the OXITEST reactor accelerate the lipid's oxidation process that in normal conditions can last weeks or months and provide fast, accurate and reliable results for Food & Feed, Cosmetic, Pharma and Petrochemical industries. 

The OXITEST provides added value information for Quality Control and Research & Development Labs for: 

  • Quality control of raw materials and ingredients 
  • Transportation and effects on goods
  • Storage period studies
  • Product Development and behavior
  • Formula Optimization 
  • Ingredient and alternative ingredients testing
  • Process optimization
  • Packaging study and alternative packaging comparison 


Representative results testing the whole sample

Representative results testing the whole sample


The OXITEST reactor subjects the sample to a high oxidative stress environment in order to evaluate, in a short period of time, the resistance to fat oxidation: 

  • Established over-pressure of pure oxygen (6 bar, degree 5.0)
  • High constant temperature, 90 °C  

With the OXITEST Method, the stability test is performed directly on the sample as it is solid, liquid or doughy

The method's key advantage is that the OXITEST ensures representative results without extensive sample preparation

Other components of the sample matrix such as chemical oxidants or transition metal can promote oxidation and the use of extracted matter may not be a suitable predictor of stability

The Induction Period IP

The Induction Period IP


The results of the OXITEST are expressed through the IP Induction Period. 

The IP is the time required to reach the starting point of oxidation, corresponding to either a level of detectable rancidity or a sudden change in the rate of oxidation.

The longer the Induction Period, the higher the stability against oxidation over time. 

 

OXISoft™ software powerful and intuitive

OXISoft™ software powerful and intuitive


The OXITEST is entirely controlled via PC through the intuitive OXISoftTM software which is able to control up to 4 OXITEST simultaneously and independently. The OXISoft™ is quick and easy-to-use, at a glance you always have the program parameters, work conditions and results. 

The software comes with multi-lingual support and a pre-installed library of methods related to a wide range of sample types, you can use these, modify them and create your own methods!

Data management, reportiing and archive with the following test types: 

  • Repeatability test
  • Freshness test
  • Formulas comparison
  • Packaging comparison
  • IP during ageing
  • Estimated shelf life


 

Premium titanium parts

Premium titanium parts


The oxidation chambers, sample holders and covers are made of titanium, a premium material guaranteeing: 
 

  • High resistance
  • Excellent chemical compatibility;
  • Easy cleaning 
  • Cost savings since no disposable consumables are required.

Benefit form cloud-bases services with VELP Ermes

Benefit form cloud-bases services with VELP Ermes

The OXITEST  thanks to its connectivity to VELP Ermes allows you to reduce routine operations thanks to the real-time monitoring of your test wherever you are, at any time from PC, smartphone and tablet. 
  • Real-time monitoring and notification 
  • Maximum security and data protection
  • Anytime access to your data via PC, smartphone and tablet
  • Enhanced Service Support (VELP and partners)
  • Immediate Software Updates
  • Create and share reports, track trend and get useful insights

Models

Please select the model:
Velp.com

cod. {{::variant.code}}
* {{::variant.shipment}}
${{::variant.promoPrice ? variant.promoPrice : variant.price | format}} ${{::variant.price | format}}

{{::includedAccessories.title}}

Velp.com
{{accessory.title}}
cod. {{accessory.code}}

{{::requiredAccessories.title}}

Velp.com
{{accessory.title}}
cod. {{accessory.code}}
${{accessory.promoPrice ? accessory.promoPrice : accessory.price | format}} ${{accessory.price | format}}

{{::optionAccessories.title}}

Velp.com
{{accessory.title}}
cod. {{accessory.code}}
${{accessory.promoPrice ? accessory.promoPrice : accessory.price | format}} ${{accessory.price | format}}
Model:
Included/required accessories: {{(includedAccessories ? includedAccessories.accessories.length : 0) + (requiredAccessories ? requiredAccessories.accessories.length : 0)}} (${{requiredAccessoriesPrice | format}})
Optional accessories: {{optionAccessoriesCount}} (${{optionalAccessoriesPrice | format}})
Add to cart
Request a quote
Model:
Included/required accessories: {{(includedAccessories ? includedAccessories.accessories.length : 0) + (requiredAccessories ? requiredAccessories.accessories.length : 0)}} (${{requiredAccessoriesPrice | format}})
Optional accessories: {{optionAccessoriesCount}} (${{optionalAccessoriesPrice | format}})
Add to cart
Request a quote

TECHNICAL DATA

Number of oxidation chambers: 2
Capacity single chamber: up to 100 ml
Pressure range: 0 - 8 bar
Temperature range: from room temp. to 120 °C
Max deviation from the set temperature ≤ 0.5 °C
Reproducibility of set temperature ≤ ± 0.2 °C
Interface: USB
Connectivity Cloud via LAN or Wi-Fi
Power 900 W
Power supply 115 V / 60 Hz - 230 V / 50-60 Hz
Weight: 16.5 Kg (36.3 lb)
Dimensions (WxHxD): 365x190x485 mm (14.6x7.6x19.4 in)
Overpressure Safety valve
Out-range temperature Visual alarm
Damaged probe Visual alarm

Brochures & Leaflets

VELP Scientifica invites you to download brochures and leaflets in order to explore our premium quality solutions and to have all the major key arguments, features and specifications of a product in your hands, in any place, and at any time.

Application notes

Choose among a comprehensive library of Application Notes / White Papers and learn more on how to optimize the performance of your VELP instruments. These documents offer typical analyses of well-known samples, together with official references and suggestions, to make you an expert!

Certifications

Our compliance to statutory rules and regulations worldwide.
With the CE mark, VELP Scientifica declares that the products are designed and manufactured in compliance with the essential safety requirements of the European Directive on Safety.
The Certification Body (CB) Certificate is an international program created by the IECEE for the acceptance of product safety test results among participating laboratories and certification organizations around the world.
The cNEMKOus mark ensures this product is designed and manufactured in compliance with the International Directive on Safety IEC/EN 61010-1. The cNEMKOus mark has the same legal status as any other NRTL/SCC accredited marks, for U.S. and Canada.
Service offering
Close to our customers: we are committed to supporting you anytime, anywhere
FAQ
Check technical sheets with answers to most frequently asked questions
What sample preparation does the OXITEST require?
The OXITEST does not require prior fat extraction, it is always possible to analyze the sample as it is (solid, liquid or paste).

The sample preparation operations are very easy and fast and consist of proper homogenization:
- for solid samples, just grinding
- for liquid (ex. oils) it is only required to stir it
Which are the standard working condition of OXITEST?
The sample placed inside the two chambers is submitted to:
- established over-pressure of pure oxygen (6 bar, degree 5.0)
- high constant temperature, 90 °C
The above conditions are the most suitable to test most of the food samples.
How to define the sample weight?
The quantity of sample to be used for the analysis depends both on the lipid content and the intrinsic characteristic of the tested element (i.e., Unsaturated Fatty Acids).
As a general rule, the less fat contained in the sample the more quantity is required for the analysis. (Sample amount per chamber: from 5 to 40 g).
Why is it important that oxygen is pure (5.0)?
The higher the purity of the oxygen, the faster the analysis is performed.

To compare several results, the analyses must have been performed at the same oxygen purity level.
Siglacom - Internet Partner