search

Press ENTER to search or ESC to close

NDA 702 Dumas Nitrogen Analyzer

Versatile and cloud-enabled elemental analyzer for Nitrogen and Protein determination according to the Dumas combustion method. Dual carrier gas: Helium and Argon.
Contact a specialist
Add to favorites
NDA 702 Dumas Nitrogen AnalyzerF30800080
Close

The perfect solution to maximize your productivity

The perfect solution to maximize your productivity

NDA 702 Dumas elemental analyzer is the best solution for high throughput labs looking for a fast and safe analyzer with the possibility to choose between Helium and Argon as carrier gas. 

The NDA 702 is powered by the DUMASoftTM software and produces N/Protein results in just 3 to 4 minutes totally unsupervised and cloud-enabled. 
 
NDA 702 is dramatically faster, easier, and safer than a traditional Kjeldahl system. 

The NDA 702 is a safe analyzer that does not require aggressive chemicals or time-consuming analysis steps, just prepare your sample and walk away! 

Versatile analyzer for solid and liquid samples

Versatile analyzer for solid and liquid samples

With the NDA 702, you can load different matrices of solid, semi-solid, and liquid samples at the same time.

VELP NDA 702 elemental analyzer is designed to work 24/7, 365 days a year with fast and easy routine maintenance.

The electronic autosampler is supplied with a disc of 30 positions and can be expanded to accommodate up to 117 samples.

The lowest LOD in the market of  0.001 mgN with Helium and the RSD lower than 0.5% (EDTA) assure you high precision results and excellent reproducibility.  

Efficiency for your lab

Efficiency for your lab


NDA 702 analyzes samples of up to 1 g and reduces operating costs thanks to VELP engineering and genuine consumables with extended lifetime. Furthermore, NDA 702 allows cost reduction related to Helium availability thanks to the seamless choice of Argon. 

  • The NDA 702 LoGasTM TCD works with no reference gas ensuring accuracy and precision; 
  • Very low oxygen consumption thanks to optimized combustion;
  • The maintenance-free DriStepTM water trap is a physical trap that removes 99% of water, reducing the cost of chemicals;
  • NDA 702 is easy to install and is extremely compact saving valuable bench space in your lab
VELP TEMS technology drastically reduces wastes compared to wet chemistry N/protein determination methods. 

NDA 702 Nitrogen Analyzer Working Principle

NDA 702 Nitrogen Analyzer Working Principle


The Dumas method starts with the combustion of the sample which takes place inside the VELP combustion furnace (CF) at a temperature higher than 1000°C to obtain elemental compounds. 

Water separation is performed in 2 steps in the NDA 702. The first is the maintenance-free physical trap DriStep™ (WT1) strategically placed after combustion and the second is a chemical trap (WT2) that ensures the complete elimination of residual 1% of water.

Between the two traps, the flow of gases passes through the reduction furnace (RF) where NOX  compounds are transformed into molecular nitrogen N2.

Afterward, the CO2 is trapped by the unique self-regenerating VELP CO2 adsorbers

At this point, elemental nitrogen is detected by the innovative thermal conductivity detector TCD LoGas™ which will send the data to DumaSoftTM to calculate the amount of Nitrogen and Protein. 

DUMASoft™ Intuitive Operations

DUMASoft™ Intuitive Operations

We have designed the NDA 702 to ensure maximum ease of use with the DUMASoftTM intuitive User Interface. Control the instrument's status for the main window, at a glance. 

Setting up an analysis is extremely simple. The database and real-time graph are easily accessible and with the connection to a balance preparing a test is even faster. 

The DUMASoftTM contains an extensive library of preinstalled methods, multilingual support, and reporting functions with export to .csv, LIMS, and xls format.  

Create and manage calibration curves, assign a name, and always be ready to use the most suitable one.

Run the complete Leak Test and choose whether to run it on the whole circuit or targeted by zone, after replacing a consumable for example. 

The NDA 702 software can be upgraded with the optional 21 CFR Part 11 Package for Pharmaceutical, Cosmetic, and Food industry laboratories that require compliance with FDA regulations. 

Adding value to automation via the cloud

Adding value to automation via the cloud

NDA 702 thanks to its connectivity to VELP Ermes allows you to reduce routine operations thanks to the real-time monitoring of your elemental analyzer wherever you are, at any time. 

NDA 702 is designed for continuous work with fully automated processes, VELP Ermes allows you to manage multiple instruments, consumables, workflows and to drastically reduce diagnostic time to ensure a superior level of service with maximum data security and protection of your data.

Immediate notifications and alerts will allow you to be always informed about the status of your analysis and thanks to the remote interruption you will have total control of your processes ensuring maximum security.

Access the database of your instrument in total security through the VELP Ermes platform and work with your colleagues creating and sharing reports from PC, smartphone and tablet.  

Tecnologia TEMS™

Save Time, Energy, Money and SpaceSave Time, Energy, Money and Space
NDA 702 Elemental Analyzer works with the innovative TEMS™ benefits, for unmatched savings.

Time Saving: rapid heating reduces wasted time
Energy Saving: limited energy consumption thus cutting CO2 emissions
Money Saving: cost reduction for each analysis
Space Saving: the narrow footprint saves valuable laboratory bench space

Models

Please select the model:
Velp.com

cod. {{::variant.code}}
* {{::variant.shipment}}
${{::variant.promoPrice ? variant.promoPrice : variant.price | format}} ${{::variant.price | format}}

{{::includedAccessories.title}}

Velp.com
{{accessory.title}}
cod. {{accessory.code}}

{{::requiredAccessories.title}}

Velp.com
{{accessory.title}}
cod. {{accessory.code}}
${{accessory.promoPrice ? accessory.promoPrice : accessory.price | format}} ${{accessory.price | format}}

{{::optionAccessories.title}}

Velp.com
{{accessory.title}}
cod. {{accessory.code}}
${{accessory.promoPrice ? accessory.promoPrice : accessory.price | format}} ${{accessory.price | format}}
Model:
Included/required accessories: {{(includedAccessories ? includedAccessories.accessories.length : 0) + (requiredAccessories ? requiredAccessories.accessories.length : 0)}} (${{requiredAccessoriesPrice | format}})
Optional accessories: {{optionAccessoriesCount}} (${{optionalAccessoriesPrice | format}})
Add to cart
Request a quote
Model:
Included/required accessories: {{(includedAccessories ? includedAccessories.accessories.length : 0) + (requiredAccessories ? requiredAccessories.accessories.length : 0)}} (${{requiredAccessoriesPrice | format}})
Optional accessories: {{optionAccessoriesCount}} (${{optionalAccessoriesPrice | format}})
Add to cart
Request a quote

Consumables and accessories for NDA 702

Consumables and accessories for NDA 702

Using original VELP consumables will maximize the performance of the NDA 702 and with VELP accessories your daily work will be easier and faster. 
  • Receive everything you need with a single code with 1000, 2000 and 4000 analysis  kit;
  • Quartz and metal reactors and pre-packaged reactors; 
  • Ash inserts in 3 different materials to meet all application needs; 
  • The innovative VcopperTM to increase the life and efficiency of the reduction reactor; 
  • Superabsorbent Powder to easily manage the preparation of liquid samples; 
  • and much more...
Velp.com
21 CFR part 11 package for Elemental Analyzers
cod. A00000455
Velp.com
Anhydrone, 454g
cod. A00000225
Velp.com
Ceramic ash collector with bottom
cod. A00000198
Velp.com
Cleaning kit for metallic ash collector
cod. A00000353
Velp.com
Closing device tin foil cup
cod. A00000217
Velp.com
Copper oxide, 50g
cod. A00000157
Velp.com
Disc 1 for capsules for autosampler
cod. A00000390
Velp.com
Disc 2 for autosampler
cod. A00000199
Velp.com
Disc 2 for capsules for autosampler
cod. A00000420
Velp.com
Disc 3 for autosampler
cod. A00000200
Velp.com
Disc 4 for autosampler
cod. A00000201
Velp.com
EDTA Certified, 100 gr
cod. A00000149
Velp.com
High temperature sealing grease
cod. A00000236
Velp.com
IQ/OQ/PQ NDA 702 Manual
cod. A00000192
Velp.com
Kit approximately 1000 analyses for NDA - CN
cod. A00000194
Velp.com
Kit approximately 2000 analyses for NDA - CN
cod. A00000270
Velp.com
Kit approximately 4000 analyses for NDA - CN
cod. A00000271
Velp.com
Kit for TOC/sample preparation
cod. TA00000378
Velp.com
Metal reactor tube
cod. A00000321
Velp.com
Metallic ash collector
cod. A00000322
Velp.com
Mold for tin foils 50x50mm
cod. A00000262
Velp.com
Oat meal, 30g
cod. A00000318
Velp.com
Pre-packed combustion reactor
cod. A00000158
Velp.com
Pre-packed reduction reactor
cod. A00000226
Velp.com
Quartz ash collector
cod. A00000161
Velp.com
Quartz reactor tube
cod. A00000162
Velp.com
Quartz wool, 50 g
cod. A00000154
Velp.com
Silver foil 35x35 mm, 100 pcs
cod. A00000371
Velp.com
Super-Absorbent Powder, 10 g
cod. A00000317
Velp.com
Tin capsules 6x18 mm, 100 pcs
cod. A00000482
Velp.com
Tin capsules 8x20 mm, 100 pcs
cod. A00000483
Velp.com
Tin Foil Cups 35x35 mm, 150 pcs
cod. A00000153
Velp.com
Tin foils 50x50 mm, 450 pcs
cod. A00000260
Velp.com
Vcopper High Reduction Efficiency, 470 g
cod. A00000240
Velp.com
VELP Ermes 1 year Connection
cod. E00010012
Velp.com
VELP Ermes 3 years Connection
cod. E00010036
Velp.com
Velpcatalyst with inert layer, 36 g
cod. A00000320

TECHNICAL DATA

Method of analysis: Nitrogen determination according to Dumas method (combustion)
Analysis time: 3/4 minutes
Detector: TCD (Thermal Conductivity Detector)
Sample weight: Up to 1 g
Autosampler type: Electronic
Autosampler capacity: Up to 4 discs, 30 positions each (up to 117 samples)
Detection range N: ppm up to 200 mg abs. (or 100 %)
Reproducibility (RSD): < 0.5% for EDTA standards (9.57%N)
Recovery: > 99.5%
Combustion temperature: 1100 °C / 2012 °F
Carrier gas: Helium or Argon (grade 5.0)
Combustion gas: Oxygen (grade 5.0)
Connectivity Ermes Cloud Platform via Wi-Fi or LAN connected to a PC
Interfaces: USB; RS232
Weight: 54 kg / 119 lb
Dimensions (WxHxD): 655x510x410 mm (H 690 mm with autosampler)
25.8x20.1x16.1 in (H 27.0 in with autosampler)
21 CFR part 11 compliance: Yes, optional package available
Official references: ISO 16634; ISO 14891; AOCS Ba 4e-93, AOAC 992.23; AACC 46-30; ICC 167, ASBC Barley 7C; AOCS Ba 4f-00; AOAC 992.15; ASBC AOAC 997.09; OIV-MA-AS323-02A; AOAC 990.03; AOAC 993.13; ISO 13878; EN 16168, etc.

Brochures & Leaflets

VELP Scientifica invites you to download brochures and leaflets in order to explore our premium quality solutions and to have all the major key arguments, features and specifications of a product in your hands, in any place, and at any time.

Application notes

Choose among a comprehensive library of Application Notes / White Papers and learn more on how to optimize the performance of your VELP instruments. These documents offer typical analyses of well-known samples, together with official references and suggestions, to make you an expert!

Certifications

Our compliance to statutory rules and regulations worldwide.
With the CE mark, VELP Scientifica declares that the products are designed and manufactured in compliance with the essential safety requirements of the European Directive on Safety.
The Certification Body (CB) Certificate is an international program created by the IECEE for the acceptance of product safety test results among participating laboratories and certification organizations around the world.
The cNEMKOus mark ensures this product is designed and manufactured in compliance with the International Directive on Safety IEC/EN 61010-1. The cNEMKOus mark has the same legal status as any other NRTL/SCC accredited marks, for U.S. and Canada.
Service offering
Close to our customers: we are committed to supporting you anytime, anywhere
FAQ
Check technical sheets with answers to most frequently asked questions
How frequently do I need to check my calibration curve?
Since the accuracy of the calibration curve strictly depends on the TCD, it can be used for several months. It is suggested to periodically verify its precision and if necessary, determine the correction factor.
What are the drivers of Oxygen and gas consumption?
Oxygen and carrier gases consumption depends on the daily use of the instrument and the method applied to perform the analysis. The software feature “help/computation” estimates the consumption of both Helium and Argon by considering the method and the number of analyses per day.
How can I choose the right ash collector?
From an analytical point of view, the ash collector material does not impact the result of the analysis.

The choice depends on the sample matrix or on the preparation step:
- Quartz ash collector is suitable for almost all types of samples
- Ceramic ash collector is suitable for the majority of samples, except those with complex matrix (high percentage of fats or carbohydrates)
- Metal ash collector is suitable for the majority of samples, except samples prepared with acids (samples: NCN - NPN - TOC). Metal ash collectors are a reusable and cost-effective solution.
Are the Dumas combustion and the Kjeldahl method giving different results?
The Kjeldahl method gives as a result of the analysis the Total Kjeldahl Nitrogen (TKN), while the Dumas combustion method gives as result the Total Nitrogen (TN).

You can find additional information by clicking here
Siglacom - Internet Partner